Product Codes for Spiral Wound Modules
Operating Condition for Spiral Wound Modules
SN- / ID- / PD- | FG | SH | CR | AR | HC | HA | HP | TR | |
Max. operating pressure loss (bar) | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 |
Max. Temperature (。C) | 50 | 50 | 75 | 50 | 50 | 75 | 75 | 50 | 80 |
pH range during filtration | 2-11 | 2-11 | 2-11 | 3-12 | 1-12 | 3-14 | 0-12 | 2-11 | 2-11 |
Outer wrap | Spacer | FRP | Spacer | FRP | FRP | O-Shell | O-Shell | FRP | FRP |